MAN.241 Rev.5 ENG - Use and maintenance manual S23 page 86 of 127
If an intervention that is different from the
following ones is necessary, ask the Tech-
nical Assistance Service for authorization
and instructions.
8.1 Daily maintenance
Every day, before starting the MEWP, perform the
following operations:
All the following checks are to be per-
formed operating the MEWP from the
emergency control station and without an-
yone inside the basket.
Perform the following
testing operations by us-
ing the (emergency) con-
trols placed on the turret
when no one is aboard:
o stabilize the MEWP;
o lift and lower the tele-
scopic boom;
o lift and lower the jib;
o clockwise and coun-
terclockwise rotate the
turret;
o extend and withdraw
the telescopic boom.