Page #88 background image
MAN.241 Rev.5 ENG - Use and maintenance manual S23 page 87 of 127
THE BASKET FLOOR
MUST ALWAYS KEEP A
HORIZONTAL LEVEL.
Check the functioning of
the outriggers block
valves, keeping the boom
lifted:
o lower the outriggers
and level the MEWP;
o push the emergency
button to turn off the
engine;
o operate the lever for
the lifting and lowering
of the outriggers.
OUTRIGGERS SHALL
NOT MOVE.
It is
strictly forbid-
den to use
the MEWP.
Contact the
Service.
C.M.C.
Operations
If negative
result:
by
Check the functioning of
the block valve of the
boom extension/lifting
cylinder:
o set vertically and ex-
tend the boom;
o push the emergency
button to turn off the
engine;
o operate the lever for
the telescopic boom
extension and with-
drawal;
o operate the levers for
the lifting and lowering
of the telescopic boom.
BOOMS SHALL NOT
MOVE.
It is
strictly for-
bidden to
use the
MEWP.
Contact the
Service.
C.M.C.