description of the
error
Cause
Remedy
Personnel
Real-time module is
blocked
On Windows, other
programs are still
running in the
background
Close programs in the
background of Windows
Operator
Energy saving mode for
the USB port is active
Disable power saving
mode in the BIOS
qualified
personnel
Machine travels a
short distance and
stops abruptly
USB dongle is not
inserted properly or not
at all
Check the USB dongle
for correct fit
Operator
Machine jammed and
cannot be moved
Lack of care and
maintenance
Clean, re-lubricate if
necessary repair by
manufacturer
Operator /
manufacturer
Machine does not
recognize the reference
switch
Feed homing in software
incorrectly set
Set guideline 5mm/sec in
software
qualified
personnel
Reference switch is
defective
Replacement or repair
Personnel /
Manufacturer
Increased backlash
Worn Nylatronnut
achieved by lack of
maintenance or reached
service life
Replacement or repair
manufacturer
Trapezoidal spindle
worn by lack of
maintenance
Replacement or repair
manufacturer