98-145510-E Appendix E: System messages E-5
0810B-0 ERROR Antenna software
version
An error has occurred during upload of software to the
antenna, the antenna software version is not as
expected. Either the software in the ACU does not meet
the minimum version required by the antenna, the
software image in the ACU is corrupted or the upload
procedure failed because of a communication error.
0810C-0 ERROR File system integrity One or more file system partitions are corrupt. You may
have lost your settings and collected statistics. If
restarting the system does not help, contact your service
partner.
0810E-0 ERROR RF calibration The RF calibration is not valid.
08840-0 WARNING Master PLL lock The master PLL has lost lock. Check the input reference
signal.
09000-0 ERROR KDM 3V3 supply Internal 3V3 voltage supply error in the KDM.
09001-0 ERROR KDM 12V supply Internal 12V voltage supply error in the KDM.
09002-0 ERROR KDM display Display hardware error in the KDM.
09010-0 ERROR KDM link/SW version Link to the KDM module could not be established. Either
the KDM board is malfunctioning, or - if the system
software has just been updated - the software is too old
and is not compatible with the KDM hardware.
0B000-0 ERROR PSM production data Missing or invalid production data in the PSM. Replace it.
0B001-0 ERROR NMEA 2000 identifier Missing or invalid production data in the PSM. Replace it.
0B010-0 ERROR PSM link/SW version Link to the PSM module could not be established. Either
the PSM board is malfunctioning, or - if the system
software has just been updated - the software is too old
and is not compatible with the PSM hardware.
0B060-0 WARNING NMEA 0183 parse
error
Parse errors detected on the NMEA 0183 interface.
Check NMEA 0183 cable, signal levels etc.
0B061-0 WARNING Power supply
temperature
ACU Power supply temperature is high. Improve
ventilation or move to a cooler area. Info: 00000000 =
Temperature warning, system still operational, but will
shut down eventually if temperature keeps rising.
00000001 = Temperature critical, system has shut down
to protect the hardware from overheating.