Lists of events
98-145510-E Appendix E: System messages E-9
0A049-0 WARNING Azi encoder slip A slip of the azimuth encoder has been detected. If this
event is not resolved by itself after some time, check the
belt and encoder of the azimuth axis.
0A04A-0 WARNING Xel encoder slip A slip of the cross-elevation encoder has been detected.
If this event is not resolved by itself after some time,
check the belt and encoder of the cross-elevation axis.
0A04B-0 WARNING Ele encoder slip A slip of the elevation encoder has been detected. If this
event is not resolved by itself after some time, check the
belt and encoder of the elevation axis.
0A04C-0 WARNING Pol encoder slip A slip of the polarisation encoder has been detected. If
this event is not resolved by itself after some time, check
the belt and encoder of the polarisation axis.
0A04D-0 WARNING GNSS position No position available from the GNSS device or position
too old.
0A04E-0 WARNING GNSS velocity No velocity available from the GNSS device.
0A04F-0 WARNING Heading data Heading information is missing in the antenna.
0A050-0 ERROR Azi DDM
communication
Communication error between PCM and azimuth DDM.
Check SUB-D connectors and cables.
0A051-0 ERROR Xel DDM
communication
Communication error between PCM and cross-elevation
DDM. Check SUB-D connectors and cables.
0A052-0 ERROR Ele DDM
communication
Communication error between PCM and elevation DDM.
Check SUB-D connectors and cables
0A053-0 ERROR ISM communication Communication error between PCM and ISM. Check
SUB-D connectors and cables.
0A054-0 ERROR PMM communication Communication error between PCM and PMM. Check
SUB-D connectors and cables.
0A055-0 WARNING Azi DDM warning The azimuth motor controller has temporarily observed
an unusual situation for temperature, voltage, current or
velocity. No user interaction required.
0A056-0 WARNING Xel DDM warning The cross-elevation motor controller has temporarily
observed an unusual situation for temperature, voltage,
current or velocity. No user interaction required.
0A057-0 WARNING Ele DDM warning The elevation motor controller has temporarily observed
an unusual situation for temperature, voltage, current or
velocity. No user interaction required.
Event ID Severity Description Explanation
Table E-2: Event messages for antenna (Continued)