EasyManua.ls Logo

Cognex In-Sight 1721 - Adjust the Focus; Figure 4-8: Location of Focus Adjustment Screw

Cognex In-Sight 1721
56 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Installing In-Sight
®
1720 Series Wafer Readers
27
4.4 Adjust the Focus
The recommended working distance range is 1 to 80mm for the wafer reader in the vertical
position. If using the horizontal mirror mount, the recommended working distance range is 1
to 56.0mm.
Once the working distance is established and an image is acquired, the focus can be
adjusted using the focus adjustment screw (M3 hex screw), located in the center of the wafer
reader’s front face-plate (see Figure 4-8). To adjust the focus, use a 2.5mm Allen wrench.
Turn the focus adjustment screw clock-wise if the wafer reader is moved closer to the wafer;
turn the screw counter clock-wise if the wafer reader is moved farther away from the wafer.
Figure 4-8: Location of Focus Adjustment Screw

Table of Contents

Related product manuals