6.4 Error Handling
The Collamat 8600/9100 is able to report up to 16 different errors. The way a labeler is acting after
an error has taken place, depends on the function Error Handling. This function can be program-
med in three different ways (for each of the 16 different errors):
' ' ignore the errormessage (do not show the message and do not act)
' 0 ' show the corresponding errormessage as a warning on the display – only
' 1 ' show the corresponding errormessage as a error on the display and stop the labeler
immediately
Each error is indicated and must be acknowledged by the ENTER key. Each error can be program-
med so that the labeller STOPs o the error message is only indicated. If the labeller is stopped due to
an error, then the signal relays ERROR and NOK are energized. If the labeller is not stopped, only
the relay NOK is energized. With the error key the error No. can be selected. Press 0 or 1 key to
select Continue or Stop. Press the dot ' '-key to suppress the error identification (ignore).
[ / ] Error-No.
[0/1/.] Cont./Stop
Continue at
Label Stock
The following types of errors can be selected for error handling:
Not Ready No LSC-Adjust. Profiling Speed
TUNIT / Paper end Nonstop mode Time Control
Position too short Label too long Division by zero
Max. Speed LSC Counter Predispensing too short
Label Stock Drive not ready
Rewinder full Undervoltage
The exact description of the error messages and their prevention are described
in the chapter 'Error messages' in the Technical Appendix.
programmer
STOP
User level:
Operating mode:
5999.530-01E 14.01.2004 CSWM 4 34