8.4 Error messages
If during operation an error occurs, this will be indicated on the LCD by an error message. Each er-
ror message has to be acknowledged by the ENTER key. If several errors occur at the same time,
they have to be acknowledged one after each other. All events causing an error message stop the
labeller or only a warning message appears. An error causing a labeller stop activates the ERROR
and NOK relay signals. If only a warning is indicated, only the NOK relay signal is activated. The
acknowledgement with the ENTER key deactivates these signals.
The following table shows all possible error messages with their error number.
Error # Error message Error cause
1 Not ready External signal READY not ready
2 TUNIT / Paper end Traction unit not closed, end of paper reached
3 Position too short Position value shorter than calculated (speed)
4 Max. speed Measured speed higher than permitted max. value
5 Label stock No label stock
6 Rewinder full Rewinder full
7 No LSC-Adjust No adjustment of label scanner possible
8 Nonstop mode Error in one of the labellers in nonstop mode
9 Label too long Label dispensed longer than entered label length
10 LSC Counter A further gap was scanned during predispensing
11 Drive not ready Motor driver card signals an error or is not ready
12 Undervoltage Undervoltage of mains scanned
13 Profiling speed Speed higher than max. speed
14 Time observing Internal processor monitoring
15 Division by zero Internal software error
16 Predispensing too short Predispensing is too short for the actually measured speed
5999.530-01E 14.01.2004 CSWM 4 45