6. When using the SkyReach in the Loading System MkII unit, the Top
Column 4.7 can be used to provide an anchor point located 4,7 m above
ground level. If greater working height is preferred, then chose the
SkyReach Adaptor 5.9 instead. With this solution, the anchor point will be
located 5,9 m above ground level. The following instructions can be
applied to both of the solutions but the illustrations are showing the Top
Column 4.7 only.
With the Top Frame still standing on the ground, insert the Top Column
4.7/SkyReach Adaptor 5.9 unit into the Top Frame, observing that the
Insertion Marking Label is in position, see Figure 25.
Figure 25. Insertion Marking Label on Top Column 4.7.
Make sure that the Top Column 4.7/SkyReach Adaptor 5.9 is
inserted the correct length into the Sleeve. Insertion Marking Label
on Top Column 4.7/SkyReach Adaptor 5.9 must be aligned with
upper edge of Top Frame Sleeve for a safe and proper installation.
7. Using a forklift truck, place the forks underneath the horizontal tubes of
the Top Frame, spread the forks as wide as possible and then, if needed,
secure the Top Frame assembly with the two supplied Combistraps
before lifting. Straps shall be attached diagonally to each fork to ensure a
safe lift, see Figure 26 below. Remember that the straps should be
tightened firmly.
NOTE