EasyManua.ls Logo

Comtech EF Data Memotec NetPerformer SDM-8400 - Troubleshooting Tips

Default Icon
78 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
NetPerformer SDM-8400 Hardware Installation Guide
5-2 Memotec
5.1 Troubleshooting Tips
Symptom Possible Problem Solution
Unit does not start,
with:
PWR LED off
ST LED off
AL LED off
No power to unit Make sure power cord is properly
plugged into the power inlet on the
unit, and the power outlet on the
wall
Check power cord and replace
immediately if damaged
Make sure power outlet has power
Unit does not start,
with:
PWR LED amber
ST LED any state
AL LED any state
Unit may be faulty Contact Technical Support for
assistance (see “Technical Sup-
port” on page 1-6)
Unit starts, with:
PWR LED green
ST LED any state
AL LED red
A software reset occurred Enter DA at the console command
line to view the alarms
If a soft start (rst) alarm has been
logged with the notation M=xx
A=xx D=xx, enter ER to dump the
Exit Record. Send to NetPer-
former Technical Support
Enter CE (Clear ERR/DIAG LED)
to turn the AL LED off
Unit starts, with an
alarm message of the
type:
An error has
occurred
(0x00100000
0xC0000002),
please call the tech-
nical support.
A hardware error occurred Enter DA at the console command
line to view the alarms
Contact Technical Support and
provide alarm codes
Table 5-1: Troubleshooting symptoms, problems, and solutions

Table of Contents