Cleaning the Volatile Trap on the
Demister
1 Stop the dryer and lockout the main power.
2 Remove the thumbscrews then remove the volatile demister cover.
3 Remove the demister by pulling it out from the housing.
4 Clean the assembly using a mild soap and water. Let the assembly dry thor-
oughly before installation.
Note: In cases of heavy volitales, steam cleaning or the use of solvents, such as acetone, may be
necessary. Be sure to test a small area with the solvent you have selected to be sure there is no
adverse reaction.
5 Insert the demister carefully back into
the housing.
6 Inspect the condition of the gasket. If
it is damaged, replace the gasket.
7 Secure the cover in place using the
original thumbscrews. Make sure the
cable is not pinched between the housing
and the cover.
✐
E-1 l Appendix