Operation I 4-15
4
Operation
Program Menu Items
Item Name Item
Code
Default
Valve
Range
Alarm delay for high deviation alarm AdH 30 0 to 60 minutes (10 to 60 minutes on program
versions prior to version 1.33)
Alarm delay for low deviation alarm AdL 30 0 to 60 minutes (10 to 60 minutes on program
versions prior to version 1.33)
Alarm deviation alarm delay after start ADS 30 0 to 30 minutes on program version 1.33 and later
only
Alarm output AdO DIS Disabled (DIS) or Enabled (EnA) on program
versions 1.33 and later only
Autostart enable ASE ENA Disabled (DIS) or Enabled (EnA)
Brownout monitor brn EnA Disabled (DIS) or Enabled (EnA)
Communications Baud rate
1
bAU 96 12 to 96
Communications Modbus ID
1
bId 1 1 to 247
Communications SPI address
1
S PA 32 32 to 63
Communications type
1
COt OFF OFF, Retransmit (rEt), SPI (SPI), ModBus (bUS),
Handheld Remote (Han)
Crash Cool enabled
1
CCE DIS Disabled (DIS) or Enabled (EnA)
Derivative time dEr 5 0 to 200
Display units Unt F F or C
High deviation alarm limit HId 10 5 to 100 degrees above set point
Integral time Int 25 1 to 800
Low deviation alarm limit Lod 10 5 to 100 degrees below set point
Low pressure bypass enabled pbE dIS Disabled (DIS) or Enabled (EnA)
Panel Temperature Alarm PA e EnA Disabled (DIS) or Enabled (EnA)
Panel Temperature Readout Pte Display only
Proportional band bnd 20 1 to 300
Proportional band ratio Pbr 5 1 to 10
Pump run hours PrH 0 0 to 999 (x100)
Purge enabled (optional)
1
PuE DIS Disabled (DIS) or Enabled (EnA)
Remote heat/cool enabled
1
rHC DIS Disabled (DIS) or Enabled (EnA)
Remote Setpoint enabled
1
rSE DIS Disabled (DIS) or Enabled (EnA)
Remote Setpoint high limit
1
rSH 260 rSL to 999
Remote Setpoint low limit
1
rSL 10 -99 to rSH
Retransmit high limit
1
rEH 260 rEL to 999
Retransmit low limit
1
rEL 10 -99 to rEH
Return Temperature Probe Enable SSE EnA Disabled (DIS) or Enabled (EnA)
Seal-Saver enabled SSE EnA Disabled (DIS) or Enabled (EnA)
User high safety limit alarm HSU 260 Between factory low and high limits
User low safety limit alarm LSU 22 Between factory low and high limits
User password UPA 000 0 to 999
Vent sequence cancel temperature SCt 120 Between factory low and high limits
1
Requires the Premium Controller option (TW-P) as well as the individual option for this function.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Conair Thermolator TW-P and is the answer not in the manual?

Conair Thermolator TW-P Specifications

General IconGeneral
BrandConair
ModelThermolator TW-P
CategoryTemperature Controller
LanguageEnglish

Related product manuals