M’Ax User Guide 35
Issue Number: 4
Set parameter
at .
10.55
1
Internal
braking resistor protection disable
1
Is an external braking resistor
used?
2
Does the Drive require de-rating?
NO
Y
ES
Initiate saving the new values by
setting parameter at .
XX.00 1000
NO
S
ee in
Chapter 2 of the Installation Guide.
Planning the installation
Y
ES
9
Display shows and the motor
is being driven?
run
When the motor speed is constant,
check that the values of parameters
and are the same.
0.04 0.05
YES
3
4
After changing the setting and
while the display is in Edit mode,
press at the same time:
and
5
To use the saved values after the
next power-up, ensure parameter
is set at .
0.50 no
After changing the setting and
while the display is in Edit mode,
press at the same time:
a
nd
6
Close the
contact and ensure parameter
at .
Hardware enable
6.15 1
Drive enable
7
Display shows .
StP
The next step will start
the motor running
8
Close the contact.
RUN
O
pen the contact, then see
Appendix B .
RUN
Diagnostics
N
O
Display shows ; motor is
stopped
TrP
10
I
f the mechanical resonances occur
when the motor is running, see
in
in Appendix D
T
esting the system Specifying shaft
stiffness and load inertia
O
ptimising the Dynamic Performance.
Basic setting-up is completed.
See later in
this chapter.
Optional setting-up

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Control Techniques M'Ax 403 and is the answer not in the manual?

Control Techniques M'Ax 403 Specifications

General IconGeneral
BrandControl Techniques
ModelM'Ax 403
CategoryServo Drives
LanguageEnglish

Related product manuals