66 M’Ax User Guide
Issue Number: 4
Parameter
Range(
ô
)Default(
ð
)
Type
6.01 Stop mode selector 0~2 2 RW Txt P
6.03 ac supply loss mode selector 0 ~ 1 0 RW Uni P
6.08 Hold zero speed select 0~1 1 RW Bit
6.15 Drive enable 0~1 1 RW Bit
6.20 Powered-up time (years, days) 00.00 ~ 9.365 y.d
RO Uni S P
6.21 Powered-up time (hours, minutes) 00.00 ~ 23.59 h.m
RO Uni S P
6.31 Sequencing bit JOG FORWARD 0 ~ 1 0 RW Bit
6.32 Sequencing bit JOG REVERSE 0 ~ 1 0 RW Bit
6.33 Sequencing bit FORWARD/REVERSE 0 ~ 1 0 RW Bit
6.34 Sequencing bit RUN 0 ~ 1 0 RW Bit
6.35 FORWARD LIMIT switch 0 ~ 1 0 RW Bit
6.36 REVERSE LIMIT switch 0 ~ 1 0 RW Bit
6.44 Active supply indicator 0~1
RO Bit
6.48 DC-bus threshold voltage 0 ~ 600 400 RW Uni
6.49 Controlled-stop enabled indicator 0~1
RO Bit