9.6  Water quality
Water quality
Water hardness for water injection
Water quality
Drinking water
Soft water
Hardness [ppm] 70 - 125 (4 - 7 gpg)
TDS (total dissolved solids) [ppm] 70 - 125
Total alkalinity [ppm] 50 - 100
Water hardness for cleaning
Water quality
Drinking water
Hard water (or soft water; see above
for specification)
Hardness [ppm] 70 - 360 (4 - 21 gpg)
TDS (total dissolved solids) [ppm] 70 - 360
Total alkalinity [ppm] 50 - 100
Figures
Temperature [°F] max. 104
pH value 6.5 - 8.5
Cl
-
(chloride)
[ppm] max. 60
CI
2
(free chlorine) [ppm] max. 0.2
SO
4
2-
(sulfate)
[ppm] max. 150
Fe (iron) [ppm] max. 0.1
SiO
2
(silicate) [ppm] max. 13
NH
2
Cl (monochloramine) [mg/l] max. 0.2
9.7  Water consumption
Water consumption
6.06 mini 6.10 mini 10.10 mini
Cold water (without ConvoClean / ConvoClean+
option)
Average water consumption [gph] 0 - 4.0 0 - 4.0 0 - 4.0
Peak consumption [gpm] 0.1 0.1 0.1
Cold water (with ConvoClean / ConvoClean+ op‐
tion)
Average water consumption [gph] 0 - 5.3 0 - 5.3 0 - 5.3
Peak consumption [gpm] 1.9 2.6 2.6
Soft water
Average water consumption for sizing the water
filter
[gph] 0 - 4.0 0 - 4.0 0 - 4.0
9 Technical data
Installation Manual 63

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Convotherm 6.06 mini and is the answer not in the manual?

Convotherm 6.06 mini Specifications

General IconGeneral
BrandConvotherm
Model6.06 mini
CategoryOven
LanguageEnglish

Related product manuals