ProLine 60 - Operator's Manual 55
UK
Select to display in cycle.
In the condition of “IN”-“TES”,press to
enter the condition of test.
In the condition of POS, rotate the tire clockwi-
se, the value in the right window will increase.
Counterclockwise, decrease.
Press key to test static sensor.
In the condition of STA, press the pizeo sensor
perpendicular to the main shaft, the value in
the right window will change which means the
installation of the sensor is correct.
Press key to test static sensor.
In the condition of DYN, press the pizeo sensor.
9.3 CUSTOMER SELF-CALIBRATION
In the condition of IN-TES, select to enter
CAL -CAL, means customer self-calibration state.
We use this when the machine has not been used
for a long time or the balancing is inaccurate.
Press to enter into the program.
This function can be used after inputting tire
parameter.
*hold on pressing for 5seconds to enter
this state.
Press to enter and the display will display
“ADD”-“O”
Press to span the machine.
The window will display“ADD”-“100”,then Use
your hand to rotate the tire until all the right side
lamp light up. At this moment clip the weight of
100g at the 12 clock position outside of the tire.
Press to span the machine.
Until the span is over, you finish the self-calibra-
tion of the machine.
After complete the customer self-calibration,
it will display “SAV”-“DAT” Then the customer
self-calibration is finished.