MOBILTEX® DATA LTD.
TITLE:
RMU5 Generic Installation and Configuration Guide
Calgary, Alberta
DOCUMENT NO.:
RMU5-MAN-001
SHEET:
51 of 69
REV:
1.10
The TT-3026 transceiver attaches to the DRI1 communications expansion adapter board. The adapter provides power to
the TT-3026 unit. Before terminating the cable, feed the cable through the cable gland on the bottom of the RMU5.
Strip the cable sheathing back approximately 15cm (6”) on the un-terminated end of the cable. The cable from the TT-
3026 unit is then wired into the provided 6-contact Phoenix-style connector as shown in Figure 48. Apply cable-ties to
reduce strain on individual conductors. After completing wiring, plug the green 6-contact connector into the mating
socket on the DRI1 Easytrack Sat Interface Board (see Figure 49).
Figure 48 TT-3026 Cable Termination
Figure 49 TT-3026 Cable Plugged Into DRI1