TITLE:
RMU5 Generic Installation and Configuration Guide
DOCUMENT NO.:
RMU5-MAN-001
C. Specifications
Environmental:
Operating temperature range:
Standard battery: -35 to +60C (-31 to +140F)
Extended battery: -40 to +60C (-40 to +140F)
Storage temperature range: -40 to +80C (-40 to +176F)
Humidity: 0 to 100% RH non-condensing
Pollution Degree 2
Mounting Suitable for indoor/outdoor use
Physical:
Enclosure: Fiberglass waterproof case (IP65, NEMA 4X rated), versatile aluminum
mounting plate
Size: 183mm x 255mm x 112mm
Weight: 3.2 kgs
Power:
Operating voltage range: 20 to 25 volts AC (50/60Hz) or 20 to 35 volts DC
Power (less accessories): 5 VA maximum
Power (with accessories): 40 VA maximum
Power Source Class 2 CSA/UL approved
Processing Core:
CPU: 200MHz ARM9 processor
Memory: 32MB flash/64MB SDRAM
Operating System: Windows CE 6.0
Display: 4 line by 20 character backlit LCD
Hard Keys: 3: 1 reset/power down, 2 for up/down control
Ethernet Interface: 10/100 Base-T
PC Configuration Connection:
Electrical Connection: USB 2.0 Peripheral Device
USB Function: RNDIS
PC OS requirements: Windows XP SP2 or higher
PC application requirements: Supplied by Mobiltex
Interruption Output:
Relay drive voltage: 12 volts DC
Relay drive current: 0.75 Amps maximum
Relay contact close dwell: 0-100 ms
Relay contact open dwell: 0-100 ms
Relay contact type: NO or NC
Relay type: Solid state or mechanical
Off Time: 100 – 60,000ms in 1ms steps
Cycle Time: 200 – 60,000ms in 1ms steps
Schedules (date and time): 1
Analog Inputs(AIN1, AIN2, AIN3 & AIN4):
Measurement Category II (as per CSA C22.2 – 61010)
Maximum Operating Altitude 5000 meters above sea level
Isolation: Full galvanic isolation, +/-230V maximum to earth ground
Ranges: +/-0.158Vpeak, +/-7.5Vpeak, +/-150Vpeak
CAT II 105VRMS/150VDC (TEG Source +/- 119VDC max)
Measurement types: AC RMS and DC, simultaneous per channel
Input Impedance: 20MOhm minimum
Resolution: 16-bit
Maximum sampling rate: 20 sps