EasyManua.ls Logo

Cortalk RMU5 Generic - RMU5 Technical Specifications

Cortalk RMU5 Generic
69 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
MOBILTEX® DATA LTD.
TITLE:
RMU5 Generic Installation and Configuration Guide
Calgary, Alberta
DOCUMENT NO.:
RMU5-MAN-001
SHEET:
68 of 69
REV:
1.10
C. Specifications
Environmental:
Operating temperature range:
Standard battery: -35 to +60C (-31 to +140F)
Extended battery: -40 to +60C (-40 to +140F)
Storage temperature range: -40 to +80C (-40 to +176F)
Humidity: 0 to 100% RH non-condensing
Pollution Degree 2
Mounting Suitable for indoor/outdoor use
Physical:
Enclosure: Fiberglass waterproof case (IP65, NEMA 4X rated), versatile aluminum
mounting plate
Size: 183mm x 255mm x 112mm
Weight: 3.2 kgs
Power:
Operating voltage range: 20 to 25 volts AC (50/60Hz) or 20 to 35 volts DC
Power (less accessories): 5 VA maximum
Power (with accessories): 40 VA maximum
Power Source Class 2 CSA/UL approved
Processing Core:
CPU: 200MHz ARM9 processor
Memory: 32MB flash/64MB SDRAM
Operating System: Windows CE 6.0
Display: 4 line by 20 character backlit LCD
Hard Keys: 3: 1 reset/power down, 2 for up/down control
Ethernet Interface: 10/100 Base-T
PC Configuration Connection:
Electrical Connection: USB 2.0 Peripheral Device
USB Function: RNDIS
PC OS requirements: Windows XP SP2 or higher
PC application requirements: Supplied by Mobiltex
Interruption Output:
Relay drive voltage: 12 volts DC
Relay drive current: 0.75 Amps maximum
Relay contact close dwell: 0-100 ms
Relay contact open dwell: 0-100 ms
Relay contact type: NO or NC
Relay type: Solid state or mechanical
Off Time: 100 60,000ms in 1ms steps
Cycle Time: 200 60,000ms in 1ms steps
Schedules (date and time): 1
Analog Inputs(AIN1, AIN2, AIN3 & AIN4):
Measurement Category II (as per CSA C22.2 61010)
Maximum Operating Altitude 5000 meters above sea level
Isolation: Full galvanic isolation, +/-230V maximum to earth ground
Ranges: +/-0.158Vpeak, +/-7.5Vpeak, +/-150Vpeak
CAT II 105VRMS/150VDC (TEG Source +/- 119VDC max)
Measurement types: AC RMS and DC, simultaneous per channel
Input Impedance: 20MOhm minimum
Resolution: 16-bit
Maximum sampling rate: 20 sps

Table of Contents

Related product manuals