ELECTRICAL SYSTEM ES-2
GENERATOR REMOVAL
Remove the seat and the helmet box.
Remove the blower hood.
Loosen the impeller screws and remove
the impeller.
Immobilize the flywheel with a suitable
tool and loosen the lock nut with a
socket wrench.
Torque: 35 Nm
Special tool: ACC-00G05300011