Enclosure Protection Degree
Variable speed cooling fans
Operating Temperature Range
2
-22°F to +140°F / - 30°C to +60°C
(derating from +113°F / +45°C)
Non-Operating Temperature
Range
3
No low temp minimum to +158°F / +70°C maximum
13,123.4ft / 4000m (derating from 9842.5ft / 3000m)
Display and Communication
User Interface and Display
CPS Flex Gateway (1 per 32 inverters)
Remote Diagnostics / FW
Upgrade Functions
39.4 x 23.6 x 10.24 in. (1000×600×260mm)
Inverter:123.5lbs/56kg; Wirebox:33lbs/15kg
Mounting / Installation Angle
4
15 to 90 degrees from horizontal(vertical, or angled)
M8 Stud Type Terminal Block
(Wire range: #6-3/0AWG CU /AL, Lugs not supplied)
Screw Clamp, Neg. Busbar
5
, Wire range: #14 - #6AWG CU
Fused String Inputs (2 per
MPPT)
6
20A fuse provided (Fuse values up to 30A acceptable)