BevMax_Media_Programming_10_6_10 Page 14 of 106 08/15/2013
ErrorDescription ProbableCausePossibleSolutions
Coin Mech Tube Error. Coin mechanism not sensing a payout tube. Check for proper pay out cassette placement.
Replace the payout cassette.
Replace the coin mechanism.
Coin Mech Disabled. Coin mechanism has been disabled by the board Power down the machine and re-start.
Remove bill validator and/or card reader from system.
Replace the coin mechanism.
Reset the control board.
Replace the control board.
Exec Price Error. Executive coin mechanism error. Check for a price set outside of allowed parameters.
Replace executive coin mechanism.
No Monetary Device. No monetary device detected by the board. Check connectors to be properly installed.
Check harness for damage.
Retest without the bill validator and harnessing
Installed.
Replace the coin mechanism.
Coin Return Motor Not Control board not sensing the presence Check the connection J6 on the I/O board to the
Present. of a coin return motor. coin return motor.
Home the coin return motor.
Replace the coin return motor.
Check for damage to harnessing.
Reset or replace the control board.
Coin Return motor Run The board has determined that the coin Check the connections to the coin return motor.
Time Timeout. return motor should have arrived at home Home the coin return motor.
position, but it has not. Replace the coin return motor.
Check for damage to harnessing.
Reset or replace the control board.
Coin Return Motor Short Coin return motor has shorted out. Check connections and harnessing for damage.
Circuit. Replace the coin return motor.
Coin Return Motor Drive The coin return motor is not engaging the Check for damaged or missing drive linkage.
Failure. coin return arm on the coin mechanism. Check for proper mounting of coin mechanism.
Check for damage on coin mechanism pay out parts.