BevMax_Media_Programming_10_6_10 Page 80 of 106
08/15/2013
reading, or if the temperature is not below 41°F by the third recheck, the “HEALTH TIME” error
will remain and selections will continue to be blocked.
4. Press the 4 Key to bring up a screen that allows
you to choose the type of Temperature Units
you would like to display. Use the numeric
Keys to check one. Use the center of the OK
button to lock in the choice and return to the
setup menu.
5. Press the 5 Key will bring up a screen listing the Health Control options. When enabled, if the
temperature in the vender does not reach 41º F (5º C) within 30 minutes after the service door is
closed, a “HEALTH TIME” error will occur and lockout the enabled selection(s) from vending
until after the error is cleared. Also, if the temperature in the vender goes above 41º F (5º C) for
more than 15 minutes after the initial cool down period, a “HEALTH CONTROL” error will
occur and lockout the enabled selection(s) from vending until the error is cleared. To set
selections for Health Control Press the 5 Key.
Use the numeric Keys to choose a tray. Choosing
a tray will bring up a screen listing all the
selections on that tray. Some selection lists will
use more than one screen. Use the top and bottom
of the OK Key to scroll thru the entire list. Use
the numeric Keys to check or un-check the
selections as needed. Checked selections will be
involved in the event.
2. Space To Sales – Press the 2 Key.
Pressing the 2 Key will bring up options for toggling the Space to Sales setting on and off.
Use the numeric keys to toggle the settings in a live window between ON and OFF for each option. The
default setting for this option is ON.
Refrigeration Settings
4) Temperature Units Fahrenheit (°F)
1) Celsius (°C)
2) Fahrenheit (°F)
Tray #2
1) Set All
2) Clear All
3) 201
4) 202
5) 203
6) 204
7) 205
8) 206
Second Screen
1) 206 (repeat)
2) 207
3) 208
4) 209
Health Control
1) Tray 1
2) Tray 2
3) Tray 3
4) Tray 4
5) Tray 5
Machine Configuration
1) Refrigeration Settings >
2) Space To sales On Off
3) Picker Cup Sensor On Off