3. Use the drop-down menu to select which PTZ you wish to correct.
4. Once the desired PTZ is selected, click the POS Correct button.
5. A secondary window appears, displaying the selected PTZ’s video feed overlaid with a blue cross
hair. Move this window over to one side so you can see both the wide-angle feed as well as the
PTZ feed.
6. Use the PTZ control buttons in the settings panel to move the PTZ into position so that the cross
hairs in both video feeds point at exactly the same location in the room. It is advisable to place an
object in the center of the crosshair for reference.
7. If you are satisfied with the adjustments, click the Return button and make sure to save your
settings before exiting. If you mistakenly entered position correction mode, click Exit on the
bottom left to exit without saving.
Audio Positioning Correction
In rooms with large acoustically reflective surfaces, like windows or video walls, the camera’s audio
location skews to one side as the camera perceives audio to be slightly louder on one side of the room.
Similarly to visual position correction, these anomalies can be reduced by calibrating the camera’s audio
positioning.
To access Audio Position Correction, select Audio in the POS Correct drop-down menu and then click the
POS Correct button. No secondary video feed will appear as you review audio positioning using the
reference feed and its overlaid debug information.