Product Manual — Doc. 9311C IV-CAMHK-12-SLVR-1B • 64
VISCA Commands
1Beyond PTZ cameras can be controlled using the VISCA protocol through either a serial (RS-232 /
RS-485) or IP connection. By default, the port for IP control is set to 5500. For serial communication,
make sure the baud rate of the controller is set to 9600bps. Below is a comprehensive list of VISCA
commands that can be used to control the cameras.
Start/Stop Tracking
To start or stop tracking on the 1 Beyond Hawk camera, call the following commands:
Command Command Packet Comments
Start tracking (Recall CAM_Memory 80) 8x 01 04 3F 02 50 FF Call Preset 80, camera addr x
Stop tracking (Recall CAM_Memory 81) 8x 01 04 3F 02 51 FF Call Preset 81, camera addr x
NOTE: These commands can only be used with AutoTracker, AutoFramer, Falcon, and Hawk
cameras. Under no circumstances should presets 80 and 81 be overwritten on these cameras. Once
configured, presets 0 and 1 must not be overwritten since these are used as references to adjust
framing while tracking is active.
Privacy
The PTZcameras can be tilted backwards for privacy when the camera is not in use. To tilt the PTZ
cameras backwards, call the following commands:
NOTE:Speaker tracking must be disabled to tilt the PTZ cameras backwards.
Command Command Packet Comments
Tilt PTZ 1 81 01 06 01 12 0E 03 01 FF Tilt PTZ 1 backwards
Tilt PTZ 2 82 01 06 01 12 0E 03 01 FF Tilt PTZ 2 backwards
ACK / Completion Messages
Command Message Comments
ACK z0 4y FF
(y:Socket No.)
Returned when the command is accepted.
Completion z0 5y FF
(y:Socket No.)