65 IV-CAMHK-12-SLVR-1B Product Manual Doc. 9311C
Error Messages
Command Message Comments
Syntax Error z0 60 02 FF Returned when the command format is different or when a
command with illegal command parameters is accepted.
Command
Buffer Full
z0 60 03 FF Indicates that two sockets are already being used (executing two
commands) and the command could not be accepted when received.
Command
Canceled
z0 6y 04 FF
(y:Socket No.)
Returned when a command which is being executed in a socket
specified by the cancel command is canceled. The completion
message for the command is not returned.
No Socket z0 6y 05 FF
(y:Socket No.)
Returned when no command is executed in a socket specified by the
cancel command, or when an invalid socket number is specified.
Command
Not
Executable
z0 6y 41 FF
(y:Execution
command Socket No.
Inquiry command:0)
Returned when a command cannot be executed due to current
conditions. For example, when commands controlling the focus
manually are received during auto focus.
z = Device address + 8
Commands
Command Set Command Command Packet Comments
AddressSet Broadcast 88 30 01 FF Address setting
IF_Clear Broadcast 88 01 00 01 FF I/F Clear
Command
Cancel
8x 2p FF p: Socket No. (=1or2)
CAM_Power On 8x 01 04 00 02 FF Power On/Off
Off 8x 01 04 00 03 FF
CAM_Zoom Stop 8x 01 04 07 00 FF
Tele(Standard) 8x 01 04 07 02 FF
Wide(Standard) 8x 01 04 07 03 FF
Tele(Variable) 8x 01 04 07 2p FF p: 0(Low)to 7 (High)
Wide(Variable) 8x 01 04 07 3p FF
Direct 8x 01 04 47 0p 0q 0r 0s FF p,q,r,s: Zoom Position