thecrowgroup.com Page | 42
Chime Alarm Reset By
Parameter Description Default Configuration
Signal
The output will change its state when an detection/restore
occurs
Not selected
Time
The output will change its state and stay on by time set in output
reset time value
Not selected
Retrigger Time
Additional time will be added set in output reset time in case of
re-trigger
Not selected
Extenders
Advanced Configuration
Parameter Description Default Configuration
Add Extender
The SH-IO 2x2 is an external two-way wireless device, two
Inputs (optional 2 zones per one input by EOL resistors) and 2
Output Relays module.
Extender registration :
- Link type : ISM
- Serial number : Device’s ID No.
- Device type: IO 2x2 Relay Board
Extender Config
- set Extender inputs type: N/O, N/C , single zone device or
double zone devices
- set Extender outputs mode : N/C or N/O
- use the Extender instructions manual for connecting and
setting EOL resistors and working mode.
Led : enable
Input : 1, 2 Both N/C
Output : 1, 2 Both N/C
Delete This button is used to delete the device from the system