thecrowgroup.com Page | 49
Area Assignment
Parameter Description Default Configuration
Keypad Assigned To Area
This option assigns Area to keypads. If a keypad assigned to
one area, only it can Arm or Disarm only that area and show
states only for this area.
Area 1
User Assignment
Parameter Description Default Configuration
Keypad control on users
Any user can assigned to operate at certain Keypads. This
option controls whether a code or access tag User Can
Arm/Disarm from certain keypads.
All users
Output Assignment
Parameter Description Default Configuration
Keypad is linked to outputs
A Keypad can be assigned to an Output or multiple Outputs.
If a Keypad is not assigned to an Output a User cannot turn
that Output On or Off from the Keypad. This feature is
useful when using the access control features of the panel,
eg a User may be allowed to operate more than one Output
with their code but they will be limited to just the Output
assigned to the Keypad they are using
All users
Alarm to Output
Parameter Description Default Configuration
Keypad medical alarm to
outputs
A Keypad generated Medical Alarm can be assigned to an
Output or multiple Outputs. This can be used to operate an
audible or visual alarm connected to the Output
Keypad panic alarm to
outputs
A Keypad Panic Alarm can be assigned to an Output or
multiple Outputs. This can be used to operate an audible or
visual alarm connected to the Output
Keypad fire alarm to outputs
A Keypad generated Fire Alarm can be assigned to an
Output or multiple Outputs. This can be used to operate an
audible or visual alarm connected to the Output
Wrong Code Alarm to Output
If someone is attempting disarm the alarm by trying various
code combinations and they enter in 5 wrong codes the
panel will go into a 'Wrong Code' tamper alarm. The Alarm
can be assigned to an Output or multiple Outputs. This can
be use to operate an audible or visual alarm connected to
the Output. A correct code entry will reset the tamper
alarm
N/A
Keypad tamper alarm to
outputs
If the keypad has a Tamper Switch fitted and this switch
activated, the Tamper Alarm can be assigned to an Output
or multiple Outputs. This can be used to operate an audible
or visual alarm connected to the Output