thecrowgroup.com Page | 45
Area account numbers
Parameter Description Default Configuration
Account Number
When system sends a report to a monitoring station there must
be a unique account number programmed to identify the panel.
There is an account code for each area.
The account code is 4 digits. Each digit can be a number from 0-
9 as well as the special characters B, C, D, E & F. For SMS report
channels no need to define the account number.
All account at "0" except
the channel #8 with
account "8000" for
CrowCloud™ connection
Reporting Options
Parameter Description Default Configuration
Report Mains Failure
If this option is selected the panel will report a Mains failure
after the report delay time has expired
(see "Clock and Timers" "Delays")
All channels selected
Report Battery Low If this option is selected the panel will report a Battery Low All channels selected
Report Communication
Fail
If this option is selected the panel will report a Communication
failure.
All channels selected
Report System Tamper
If this option is selected the panel will report a Tamper Alarm on
the tamper panel is triggered
All channels selected
Report Keypad Tamper
If this option is selected the panel will report a Tamper Alarm
from a keypad fitted with a tamper switch or a wrong code alarm
from a keypad
All channels selected
Report Zone Tamper If this option is on the panel will report a Zone Tamper Alarm All channels selected
Report Zone Trouble If this option is on the panel will report a Zone trouble Alarm
Report Duress Alarm If this option is on the panel will report a Duress Alarm
All channels selected
Report Panic Alarm
If this option is on the panel will report a Panic Alarm generated
by keypad or RMT (pendant)
All channels selected
Report Manual Fire
Alarm
If this option is on the panel will report a Keypad generated Fire
Alarm
All channels selected
Report Manual Medical
Alarm
If this option is on the panel will report a Keypad generated
Medical Alarm
All channels selected
Report Zone Bypasses
If this option is on the panel will report a Manual or Auto Bypass
on a zone
All channels selected
Report Arm-Disarm
If this option is on then all Arm/Disarm signals will be reported
to a Monitoring Station
All channels selected
Report Stay Mode
Arm-Disarm
If this option is on then all Stay Mode Arm/Disarm signals will be
reported to a Monitoring Station