thecrowgroup.com Page | 62
pressing on STOP walk test /End walk test button, terminates the walk test process. The results of the walk-test will be show
on the screen to verify which detectors were triggered during the walk-test mode.
NOTE: The device’s indication LED light under test will flash green color during the walk test process.
An Output can be used for the Audible walk-test indication; the siren on the output will give a single tone for the chirp
instead of the swept tone used for alarms.
In Addition, this page provides General Display information of Accessories (zone names, device serial #, state, device type,
RSSI level , repeated zones, panel main communication (Ethernet, GSM/3G, WiFi ) status, radio frequency , panel versions
(panel firmware, RF module, DECT ULE SW version).
Control
Parameter Description Default Configuration
ARM Key button for Area ARM
DISARM Key button for Area DISARM
STAY Key button for Area STAY ARM
Log
Parameter Description Default Configuration
Log Displays the logs events from C.P to cloud
Get internal log
Displays the total logs events, from C.P. to cloud + C.P.
internal events
-
Update log Refresh the web page of the log events
Log on page Ability to increase the number of display log events
…More
Parameter Description Default Configuration
Backup config/restore/save
as Default
Ability to create new backup and restore/save as default of
the panel configuration
-
Personal Page
Option of displaying the personal page from installer
programming mode
-
Panel upgrade
Uses to upgrade the panel firmware, RF module, DECT
module from Cloud or Local file, this action is protected by
inserting installer code, in addition there are options to
create Backup and/or Restore prior the upgrade process
-
Apply default
Ability to upload default configuration file from a list which
created in save as default action in backup Config by
-
Reset Panel Connection Reset the connection socket from C.P. to cloud server
Restart Panel Restart the panel doesn’t affect the panel settings