thecrowgroup.com Page | 40
Timing
Parameter
Description Default Configuration
Output on delay time (seconds)
The 'On' delay allows the operation of the Output
to be delayed by the time programmed at this
location. If set to '0' there will be no on delay and
the Output will operate the instant, it is turned on.
The time range is 0-36000 seconds.
Disable
Output reset time (seconds)
The Reset time affects the time the output turns
on in case of alarm state. The time range is 0-
36000 seconds.
disable
Add Output
Parameter
Description Default Configuration
Learn Radio Output / Serial
number
Insert Device’s ID and type Disable
Delete Radio Output Delete existing radio output from memory disable
Output config
This function set remotely the radio output
parameters according different output devices
types such as led on/off, sounder on/off, led and
sounder timeouts, and Loudness etc.
disable
Radio Output Module / Link
type
Select device type “ ISM” , “DECT” or “ ISM
Extender” (RL1, RL2)
disable