TROUBLESHOOTING
9-1
PROBLEM
POSSIBLE CAUSE
SOLUTION
WITH THE POWER SWITCH ON,
POWER CORD DEFECTIVE OR UNPLUGGED
INSPECT AND CORRECT
NO COOLING FAN; NO DISPLAY
AC FUSE BLOWN
DETERMINE CAUSE AND REPLACE FUSE
WITH THE POWER SWITCH ON,
DISPLAY CABLE NOT PLUGGED IN TO
RECONNECT CABLE
COOLING FAN ON; NO DISPLAY
THE BACK OF THE APPLICATOR
LOSS OF 24 VDC
CALL A FACTORY REPRESENTATIVE
DEFECTIVE CABLE
REPLACE CABLE
DEFECTIVE DISPLAY BOARD
REPLACE DISPLAY BOARD
WITH THE POWER SWITCH ON,
COOLING FAN ON; DISPLAY
MAKE SURE THE DRIVE IS RUNNING
CALL A FACTORY REPRESENTATIVE
IS STUCK ON THE STARTUP SCREEN
LABEL LINER BREAKING
LABELS ARE THREADED INCORRECTLY
SEE THREADING DIAGRAM
BAD ROLL OF LABELS
REPLACE LABEL ROLL
SIDE NICKS IN LINER;
REPLACE LABEL ROLL
HEAVY DIE CUT ON LINER
ROLLER COLLARS ARE STRESSING
CHECK TO MAKE SURE GUIDE COLLARS
THE LABEL STOCK
LINE UP WITH UNWIND
SHOULD HAVE 1/64" CLEARANCE
BETWEEN LABEL STOCK AND COLLAR
ADHESIVE BUILD-UP ON PEEL EDGE
CLEAN PEEL EDGE SURFACE
PEEL BAR TENSION SPRING TOO TIGHT
RELEASE SPRING TENSION