Curtis 1244 Manual, Rev. E
M 1 T H R T L M A P Mode 1 throttle map, as %
M 2 T H R T L M A P Mode 2 throttle map, as %
M 3 T H R T L M A P Mode 3 throttle map, as %
M 4 T H R T L M A P Mode 4 throttle map, as %
F I E L D M I N Minimum field current, in amps
F I E L D M A X Maximum field current, in amps
H P D T H R E S H O L D Allowable throttle at startup, as % active throttle range
F L D M A P S T A R T Armature current at which field map takes eect, in amps
F I E L D M A P Field winding current, as % armature current
C U R R E N T R A T I O Current ratio: factor of 1, 2, 4, or 8
R E S T R A I N T Ramp restraint: 1 to 10
L O A D C O M P Load compensation: 0 to 25
H P D High pedal disable (HPD) type
3
S R O Static return to o (SRO) type
4
S E Q U E N C I N G D L Y Sequencing delay, in seconds
M A I N C O N T I N T R Main contactor interlock: On or O
M A I N O P E N D L Y Main contactor dropout delay, in seconds
W E L D C H E C K Main contactor weld check: On or O
M A I N C H E C K Main coil open check: On or O
A U X D E L A Y Auxiliary driver dropout delay, in seconds
A U X C H E C K Auxiliary coil open check: On or O
E M B R A K E D E L A Y Electromagnetic brake delay, in seconds
E M B R A K E C H E C K Electromagnetic brake open check: On or O
R E V D R V R C H E C K Reverse signal open check: On or O
C O N T P U L L I N Contactor coil pull-in voltage, as %
C O N T H O L D I N G Contactor coil holding voltage, as %
E M R R E V E N A B L E Emergency reverse function: On or O
E M R R E V C / L Emergency reverse current limit, in amps
E M R R E V C H E C K Emergency reverse wiring check: On or O
A N T I - T I E D O W N Anti-tiedown: On or O
F A U L T C O D E Fault output type
5
P E D A L I N T R L C K Pedal switch interlock: On or O
P R E C H A R G E Precharge function: On or O
N O D E A D D R CAN-Bus address: 1 through 15
7 — PROGRAMMER MENUS
Parameters Menu, cont’d