Page 3-13
Error codes are stored in a log of 20 entries, each stamped with time and date with the most recent being
the rst in the log, the oldest the last in the log. Error codes are displayed in the following format: [Log
Entry #] [Actual Error Code #] [Time] [Date], “ERR 1 141 03:49 1/14/2007”.
Press the Incline Control Keys to increment / decrement the Log count to view the next or previous error.
While displaying the error log press and hold the CLEAR button for three seconds to clear all errors. The
display will show “NO ERRORS” when cleared.
ERROR 1 - No Speed at Startup. The display commanded a belt start but the drive did not respond
with a belt speed within timed limits.
ERROR 3 - Speed Irregularity. The drive is reporting a slower speed than the display is commanding,
or a speed of zero after a correct speed had been established.
ERROR 5 - Drive Communications Lost. The display lost communications with the drive, where the
drive has not given a valid response in 350 ms.
ERROR 6 - Speed Irregularity/Overspeed. If the display has received good belt speed information at
the startup, yet the drive begins sending values outside the expected it is reported as belt speed lost.
ERROR 7 - Controller Over-Current (Fold-back). If the display receives motor current information
from the drive that is outside of desired parameters.
ERROR 8 - Approaching Over-Temperature. Internal controller temperature too high.
ERROR 9 - Display watchdog triggered. If the Display Watchdog is triggered the console will reboot.
ERROR 92 - Over Current (Output). Controller output current too high.
ERROR 93 - Over Voltage (DC Link). Internal controller voltage too high.
ERROR 94 - Over Heat (Heatsink). Controller temperature too high.
ERROR 95 - Low Voltage (DC Link). Drive measures a low voltage on the input line.
ERROR 96 - Thermal Integrator of output current. Drive measures a high current peak on the output
line.
ERROR 98 - Display Communications lost. Without drive belt movement. The drive lost
communications with the display, where the display has not sent a valid response in 400 ms.
ERROR 99 - Display Communications lost. With drive belt movement. The drive lost
communications with the display, where the display has not sent a valid response in 400 ms.
ERROR 103 - Input Current OC trip (110 VAC only). Drive measures a high current peak on the input
line.
ERROR 105 - Thermal Integrator of Input Current (110 VAC only). Input current is out of expected
range.
ERROR 140 - Can not nd home position on power-up. The display does not receive a signal from
the zero position switch during power up.
ERROR 141 - Can not nd home position in normal use. The display does not receive a signal from
the zero position switch during use.
ERROR 142 - Out of incline range (over 15% or lower than -3%). The display receives a position
switch report that is outside of expected limits.
ERROR 150 - Out of Speed Range (over 150hz). The display receives a report of belt speed that is
over the expected speed.

Other manuals for CYBEX 750T

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the CYBEX 750T and is the answer not in the manual?

CYBEX 750T Specifications

General IconGeneral
Motor3.0 HP
Incline Range0% - 15%
Max User Weight400 lbs
Heart Rate MonitoringWireless Receiver
Weight350 lbs

Related product manuals