Breadcrumb Field code Setting name Range, step
Default valu
e
Date Value
Field settings table
Installer setting at variance with
default value
9.I [2-04] R/W 40~60 min, step: 5 min
40 min
9.I [2-05] R/W 4~16°C, step: 1°C
12°C
9.I [2-06] R/W 0: Disabled
1: Enabled
9.I [2-09] R/W -5~5°C, step: 0,5°C
0°C
9.I [2-0A] R/W -5~5°C, step: 0,5°C
0°C
9.I [2-0B] R/W -5~5°C, step: 0,5°C
0°C
9.I [2-0C] R/W
0: Underfloor heating
1: Fancoil unit
2: Radiator
9.I [2-0D] R/W
0: Underfloor heating
1: Fancoil unit
2: Radiator
9.I [2-0E] R/W 0~50 A, step: 1 A
50
A
9.I [3-00] R/W 0: No
1: Yes
9.I [3-01]
0
9.I [3-02]
1
9.I [3-03]
4
9.I [3-04]
2
9.I [3-05]
1
9.I [3-06] R/W 18~30°C, step: 1°C
30°C
9.I [3-07] R/W 12~18°C, step: 1°C
12°C
9.I [3-08]
35
9.I [3-09]
15
9.I [4-00] R/W 0: Disabled
1: Enabled
2: Onl
y
DHW
9.I [4-01] R/W
0: None
1: BSH
2: BUH
9.I [4-02] R/W 14~35°C, step: 1°C
22°C
9.I [4-03] R/W 0: Restricted
1: Allowed
2: Overlap
3: Compressor off
4: Le
g
ionella onl
y
9.I [4-04]
0: Intermittent
1: Continuous
2: Of
f
9.I [4-05] 0
9.I [4-06] R/W 0: Manual
1: Automatic(normal SH/DHW ON)
2: Auto red SH/DHW ON
3: Auto red SH/DHW OFF
4: SH ON/DHW OFF
9.I [4-07]
6
9.I [4-08] R/W
0: No limitation
1: Continuous
2: Di
g
ital in
p
uts
9.I [4-09] R/W 0: Current
1: Power
9.I [4-0A] R/W
0: 1 (*1)
1: 1/1+2 (*2) (*3)
2: 1/2
3: 1/2 + 1/1+2 in emer
g
enc
y
9.I [4-0B]
1
9.I [4-0D]
3
9.I [4-0E]
6
9.I [5-00] R/W 0: Allowed
1: Not allowed
9.I [5-01] R/W -15~35°C, step: 1°C
0°C
9.I [5-02] R/W
0: Disabled
1: Enabled
9.I [5-03] R/W -15~35°C, step: 1°C
0°C
9.I [5-04] R/W 0~20°C, step: 1°C
10°C
9.I [5-05] R/W 0~50 A, step: 1 A
50
A
9.I [5-06] R/W 0~50 A, step: 1 A
50
A
9.I [5-07] R/W 0~50 A, step: 1 A
50
A
9.I [5-08] R/W 0~50 A, step: 1 A
50
A
9.I [5-09] R/W 0~20 kW, step: 0,5 kW
20 kW
9.I [5-0A] R/W 0~20 kW, step: 0,5 kW
20 kW
9.I [5-0B] R/W 0~20 kW, step: 0,5 kW
20 kW
9.I [5-0C] R/W 0~20 kW, step: 0,5 kW
20 kW
9.I [5-0D] R/W (*2)
R/O (*1)
(*3)
0: 230V, 1~ (*1) (*2)
1: 230V, 3~ (*2)
2: 400V
,
3~
(
*3
)
9.I [5-0E]
1
9.I [6-00] R/W 2~40°C, step: 1°C
25°C
9.I [6-01] R/W 0~10°C, step: 1°C
2°C
--
--
--
What is the maximum desired room temperature in heating?
Below which outdoor temperature is heating allowed?
Space heating priority temperature.
Set point correction for domestic hot water temperature.
What is the requested limit for DI1?
The temperature difference determining the heat pump ON temperature.
The temperature difference determining the heat pump OFF temperature.
Water pipe freeze prevention
Space heating priority.
What is the mimimum desired room temperature in heating?
What is the BUH operation mode?
Which electric heater has priority?
Which power limitation mode is required on the system?
--
Emergency
--
Adjust the offset on the measured room temperature
Room frost protection
What is the requested limit for DI4?
What emitter type is connected to the main LWT zone?
What is the equilibrium temperature for the building?
What is the requested limit for DI2?
What is the requested limit for DI3?
What is the requested limit for DI4?
Is backup heater operation allowed above equilibrium temperature during space
heating operation?
Which power limitation type is required?
--
What is the requested limit for DI1?
--
Backup heater voltage
What is the requested limit for DI2?
What is the requested limit for DI3?
Room antifrost temperature
--
Backup heater configuration
Operation permission of the booster heater.
--
--
Is auto restart of the unit allowed?
Adjust the offset on the measured room temperature
What is the required offset on the measured outdoor temp.?
What is the maximum allowed current over the heatpump ?
--
--
--
What emitter type is connected to the additional LWT zone?
How long must the tank temperature be maintained?
(*1) *3V_
(*2) *6V_
(*3) *9W
(#) Setting is not applicable for this unit. 4P629095-1 - 2020.09