38 Installation Manual 3P581074-2D
DGE601A52
English
Peel away the sheath and coating of the power wire to match the dimensions shown
below. You can also refer to a [strip gauge] on the terminal block cover for the coating
peeling allowance.
<Power wire (sheath, coating)> <Terminal block cover>
10 mm
10 mm
L: 45 mm
E: 40 mm
N: 50 mm
Round crimp-type
terminal (2-M4)
* Use the included round crimp-type
terminal (2-M4) for the end of the
earth wire only (eld supply possible)
When peeling, be careful not to scratch the nish of the exposed part of the cable.
Bad example
Frayed
Too short
Bent
Too long
10 mm
Good example
(3) While engaging the tab in the area marked with a triangle, attach the terminal
block cover and secure it with the screw.
01_EN_3P581074-2D.indd 38 2021/06/25 14:12:12