EasyManua.ls Logo

Daikin FL15EXV1 - Cable Size

Daikin FL15EXV1
78 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
12
Application Information
Cable Size
Model Unit
FL15EXV1 FL20EXV1 FL25EXV1 FL28EXV1 FL28EXV1
R15CXV1 R20CXV1 R25CXV1 R28CXV1 R30DXV1
Power supply cable size
Number of wire
mm
2
2.5
3
2.5
3
2.5
3
2.5
3
4
3
Interconnection cable size
Number of wire
mm
2
2.5
3
2.5
3
2.5
3
2.5
3
2.5
4
Recommended fuse A 16 16 20 20 25
Model Unit
FL35EXV1 FL40EXV1 FL50EXV1 FH62CXV1
R35DXV1 R40DXV1 R40DXY1 R50DXY1 R61DXY1
Power supply cable size
Number of wire
mm
2
4
3
4
3
2.5
5
2.5
5
2.5
5
Interconnection cable size
Number of wire
mm
2
1.5
4
1.5
4
1.5
4
1.5
4
1.5
4
Recommended fuse A 30 30 13 13 16
Model Unit
FLY15EXV1 FLY20EXV1 FLY25EXV1 FLY28EXV1 FLY28EXV1
RY15CXV1 RY18CXV1 RY20CXV1 RY25CXV1 RY28CXV1 RY30DXV1
Power supply cable size
Number of wire
mm
2
2.5
3
2.5
3
2.5
3
2.5
3
4
3
Interconnection cable size
Number of wire
mm
2
2.5
5
2.5
5
2.5
5
2.5
5
2.5
6
Recommended fuse A 16 16 20 20 25
Model Unit
FLY35EXV1
FLY40EXV1
FLY50EXV1 FHY62CXV1
RY35DXV1 RY40DXV1 RY40DXY1 RY50DXY1 RY61DXY1
Power supply cable size
Number of wire
mm
2
4
3
4
3
2.5
5
2.5
5
2.5
5
Interconnection cable size
Number of wire
mm
2
1.5
4 & 3
1.5
4 & 3
1.5
4 & 3
1.5
4 & 3
1.5
7
Recommended fuse A 30 30 13 13 16