21
Engineering & Physical Data
Engineering Data - R22 MODEL
MODEL
INDOOR UNIT FL40EXV1 FL50EXV1 FH62CXV1
OUTDOOR UNIT R40DXY1 R50DXY1 R61DXY1
NOMINAL COOLING CAPACITY
Btu/h 38000 47500 56000
W 11140 13900 16410
NOMINAL TOTAL INPUT POWER (COOLING) W 3800 5050 5593
NOMINAL RUNNING CURRENT (COOLING) A 6.23 8.48 9.40
EER W/W 2.93 2.76 2.93
REFRIGERANT CONTROL (EXPANSION DEVICE) INDOOR CAP TUBE
REFRIGERANT CHARGE kg 2.48 2.55 5.00
MODEL
INDOOR UNIT FLY40EXV1 FLY50EXV1 FHY62CXV1
OUTDOOR UNIT RY40DXY1 RY50DXY1 RY61DXY1
NOMINAL COOLING CAPACITY
Btu/h 38000 46000 56000
W 11100 13500 16410
NOMINAL HEATING CAPACITY
Btu/h 42000 52000 56000
W 12300 15200 16410
NOMINAL TOTAL INPUT POWER (COOLING) W 3450 4750 5593
NOMINAL TOTAL INPUT POWER (HEATING) W 3750 4150 4551
NOMINAL RUNNING CURRENT (COOLING) A 6.03 8.18 9.40
NOMINAL RUNNING CURRENT (HEATING) A 6.91 7.39 8.10
EER W/W 3.23 2.84 2.93
COP W/W 3.28 3.67 3.61
REFRIGERANT CONTROL (EXPANSION DEVICE) OUTDOOR CAP TUBE OUTDOOR CAP TUBE
INDOOR & OUTDOOR
CAP TUBE
REFRIGERANT CHARGE kg 2.50 2.50 5.00
POWER SOURCE V/Ph/Hz 380-415 / 3 / 50
REFRIGERANT TYPE R22
INDOOR UNIT
CONTROL
AIR DISCHARGE AUTOMATIC LOUVER (UP & DOWN)
OPERATION WIRELESS OR WIRED REMOTE CONTROL
AIR FLOW
HIGH l/s / CFM 520 / 1100 570 / 1215 731 / 1550
MEDIUM l/s / CFM 460 / 983 510 / 1082 623 / 1320
LOW l/s / CFM 410 / 877 450 / 959 472 / 1000
EXTERNAL STATIC PRESSURE (H/M/L) Pa (in.wg.) 0
SOUND PRESSURE LEVEL (H/M/L) dBA 52 / 47 / 46 52 / 50 / 49 56 / 53 / 46
UNIT DIMENSION HEIGHT X WIDTH X DEPTH mm 260 x 1538 x 634 260 x 1786 x 634 285 x 1903 x 680
PACKING DIMENSION HEIGHT X WIDTH X DEPTH mm 352 x 1620 x 734 352 x 1868 x 734 351 x 2016 x 788
UNIT WEIGHT kg 45 58 85
CONDENSATE DRAIN SIZE mm 19.1 / 3/4
FAN
TYPE BLOWER WHEEL
DRIVE DIRECT
FAN MOTOR
TYPE INDUCTION
INDEX OF PROTECTION (IP) 20 - -
INSULATION GRADE B
RATED INPUT POWER W 218 295 160 x 2
RATED RUNNING CURRENT A 0.98 1.32 0.67 x 2
MOTOR OUTPUT W 118 149 80 x 2
POLES 4
COIL
TUBE
MATERIAL COPPER
DIAMETER mm 7 7 9.52
FIN
MATERIAL ALUMINIUM
FACE AREA m
2
0.32 0.32 0.42
ROW 344
AIR QUALITY FILTER
TYPE SARANET
QUANTITY pc 345
CASING COLOUR LIGHT GREY
OUTDOOR UNIT
AIR FLOW l/s / CFM 1605 / 3400 1605 / 3400 1793 / 3800
SOUND PRESSURE LEVEL dBA 58 58 61
UNIT DIMENSION HEIGHT X WIDTH X DEPTH mm 852 x 1030 x 400 852 x 1030 x 400 852 x 1030 x 400
PACKING DIMENSION HEIGHT X WIDTH X DEPTH mm 1010 x 1180 x 514 1010 x 1180 x 514 1010 x 1180 x 514
UNIT WEIGHT kg 100 105 108
PIPE
CONNECTION
TYPE FLARE VALVE
SIZE
LIQUID mm 9.52 9.52 12.70
GAS mm 19.05 19.05 19.05
FAN
TYPE PROPPELER
DRIVE DIRECT
FAN MOTOR
TYPE INDUCTION
INDEX OF PROTECTION (IP) 54 54 54
INSULATION GRADE BBF
R RATED INPUT POWER W 257 257
272
RY RATED INPUT POWER W 276 276
R RATED RUNNING CURRENT A 1.10 1.10
1.28
RY RATED RUNNING CURRENT 1.34 1.34
MOTOR OUTPUT W 145 145 145
POLES 8
COMPRESSOR
TYPE SCROLL
OIL TYPE
MOBIL EAL ARCTIC 22CC
MINERAL OIL MINERAL OIL
OIL AMOUNT cm
3
1951 1950 1950
R RATED INPUT POWER W 3325 4498 5001
RY
RATED INPUT POWER (COOLING)
W 2956 4179 5001
RATED INPUT POWER (HEATING)
W 3256 3579 3959
R RATED RUNNING CURRENT A 5.54 7.67 8.53
RY
RATED RUNNING CURRENT
(COOLING)
A 5.26 7.29 8.53
RATED RUNNING CURRENT
(HEATING)
A 6.14 6.50 7.23
R LOCKED ROTOR AMP.
48
58
74
RY LOCKED ROTOR AMP. A 59
COIL
TUBE
MATERIAL COPPER
DIAMETER mm 7.00 7.00 9.52
FIN
MATERIAL ALUMINIUM
FACE AREA m
2
0.87
ROW 2
CASING COLOUR LIGHT GREY
ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151 (NON-DUCTED UNIT) OR ISO 13253 (DUCTED UNIT).
COOLING HEATING
INDOOR: 27°C DB / 19°C WB INDOOR: 20°C DB
OUTDOOR: 35°C DB / 24°C WB OUTDOOR: 7°C DB / 6°C WB
DAIKIN_FL(Y).indb 21DAIKIN_FL(Y).indb 21 9/27/2012 12:13:20 PM9/27/2012 12:13:20 PM