5
Application Information
Refrigerant Circuit Diagrams
Model: FL15EXV1 – R15CXV1 / FL20EXV1 – R20CXV1
COOLING OPERATION
3 WAY
VALVE
DISCHARGE
ACCUMULATOR
COMPRESSOR
RETURN
AIR SENSOR
HEAT EXCHANGER
(INDOOR UNIT)
PIPE TEMPERATURE
SENSOR
2 WAY
VALVE
COOLING
CAP TUBE
STRAINER
HEAT EXCHANGER
(OUTDOOR UNIT)
INDOOR UNIT OUTDOOR UNIT
Model: FL25EXV1 – R25CXV1
COOLING OPERATION
INDOOR UNIT OUTDOOR UNIT
RETURN
AIR SENSOR
HEAT EXCHANGER
(INDOOR UNIT)
PIPE TEMPERATURE
SENSOR
3 WAY
VALVE
DISCHARGE
ACCUMULATOR
COMPRESSOR
3 WAY
VALVE
COOLING
CAP TUBE
STRAINER
HEAT EXCHANGER
(OUTDOOR UNIT)
DAIKIN_FL(Y).indb 5DAIKIN_FL(Y).indb 5 9/27/2012 12:13:18 PM9/27/2012 12:13:18 PM