Indoor Unit: FTXS09/12LVJU SiUS091133
163 Removal Procedure
2. Remove the horizontal
blade (small).
1
Unfasten the center
shaft while bending the
horizontal blade (small)
slightly.
2
Unfasten the left shaft.
3
Unfasten the right shaft. There is a key alignment at the
right shaft. When reassembling,
insert the right shaft first while
turning.
After inserting the right shaft,
first mount the horizontal blade
to the center shaft, and then to
the left shaft.
3. Remove the fan guard.
1
Unfasten the hooks at
the lower part of the fan
guard with a flat
screwdriver.
Step
Procedure Points
(R7925)
Horizontal blade (small)
(R7926)
(R13737)
Key alignment
(R13751)

Table of Contents