SiUS091133 Indoor Unit: FTXS15/18/24LVJU
Removal Procedure 192
2.3 Removal of Electrical Box
Procedure Warning Be sure to wait for 10 minutes or more after turning off all power supplies
before disassembling work.
Step
Procedure Points
1. Layout of the parts
Preparation
Remove the front grille
according to the “Removal of
Front Grille.”
2. Remove the drip proof
plate. The shape of the drip proof plate
differs by the model.
1
Remove the screw.
2
Remove the drip proof
plate from the indoor
heat exchanger.
When reassembling, fit the hook
to the indoor heat exchanger.
1
2
3
(R16270)
1
2
3
(R16271)
Drip proof plate
(R16272)
(R16273)