EasyManua.ls Logo

Daikin FTXS-L Series - Removal of Electrical Box

Daikin FTXS-L Series
414 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
SiUS091133 Indoor Unit: FTXS30/36LVJU
Removal Procedure 228
3.3 Removal of Electrical Box
Procedure Warning Be sure to wait for 10 minutes or more after turning off all power supplies
before disassembling work.
Step
Procedure Points
1. Layout of the parts
Preparation
Remove the front grille
according to the “Removal of
Front Grille.”
2. Remove the drip proof
plate.
1
Remove the screw.
2
Remove the drip proof
plate from the indoor
heat exchanger.
When reassembling, fit the hook
to the indoor heat exchanger.
1
2
3
(R9493)
1
2
3
(R9494)
Drip proof plate
(R9496)
(R9495)

Table of Contents

Other manuals for Daikin FTXS-L Series

Related product manuals