SiUS091133 Indoor Unit: FTXS09/12LVJU
Removal Procedure 176
1.7 Removal of Swing Motors
Procedure Warning Be sure to wait for 10 minutes or more after turning off all power
supplies before disassembling work.
Step
Procedure Points
1. Remove the swing motor
for vertical blades.
1
Lift the indoor unit with
a wooden base.
2
Remove the screw
behind the drain hose,
and disconnect the
drain hose.
3
Remove the screw at
the rear, and remove
the screws on the right
and the left side of the
swing motors for
horizontal blades.
(R10323)
(R10329)
Drain hose
(R13748)
Swing motor for
horizontal blades