Outdoor Unit: RXS15/18LVJU SiUS091133
297 Removal Procedure
5.3 Removal of Electrical Box
Procedure Warning Be sure to wait for 10 minutes or more after turning off all power supplies
before disassembling work.
Step
Procedure Points
1
Remove the 2 screws
of the protection plate.
When reassembling, pass the
connecting wires through the
conduit and secure them with a
lock nut.
2
Remove the protection
plate.
3
Remove the screws
and remove the
connecting wires and
the power supply wires.
(R16955)
Protection plate
1
2
3
Lock nut
Conduit
mounting plate
Conduit 1/2 inch
(21.3mm)
(R16825)
(R16956)
(R16914)
Power supply wire