Outdoor Unit: RXS09/12LVJU SiUS091133
273 Removal Procedure
4.3 Removal of PCBs
Procedure Warning Be sure to wait for 10 minutes or more after turning off all power supplies
before disassembling work.
Step
Procedure Points
1. Remove the main PCB
and the forced operation
button PCB.
You can remove the main PCB
when you disconnect the lead
wires on the terminal board
without removing the electrical
box.
1
Layout of the main PCB
2
Remove the screw on
the terminal board.
Main PCB
Forced operation
button PCB
(R16997)
Terminal
board
(R11854)