Outdoor Unit: RKS30/36LVJU, RXS30/36LVJU SiUS091133
367 Removal Procedure
7.2 Removal of Electrical Box
Procedure Warning Be sure to wait for 10 minutes or more after turning off all power supplies
before disassembling work.
Step
Procedure Points
1 Remove the screw on
the stop valve mounting
plate.
2 Remove the screw on
the partition plate (1).
3 Remove the 2 screws
to detach the ground
wires.
Stop valve
mounting plate
(R16641)
Partition plate (1)
(R16917)
Ground wire
(R16642)