SiUS091133 Outdoor Unit: RXS09/12LVJU
Removal Procedure 274
3
Release the 2 ground
wires.
4
Pull out the forced
operation button PCB.
Disconnect the
connector [S110] to
remove the forced
operation button PCB.
Be careful of a sharp protrusion
at the back of the forced
operation button PCB.
5
Cut the clamp.
Step
Procedure Points
Ground
wire
(R16998)
Forced operation button PCB
[S110]
(R16932)