Indoor Unit: FTXS15/18/24LVJU SiUS091133
199 Removal Procedure
10
Unfasten the hook on
the right of the signal
receiver PCB.
(Then the signal
receiver PCB is lifted
up.)
11
Remove the signal
receiver PCB.
12
Disconnect the
connector.
[S48] : to control PCB
Step
Procedure Points
(R13519)
Signal receiver PCB
Signal receiver unit
(R9521)
(R9522)
[S48]