EasyManua.ls Logo

Daikin FTXS-L Series - Page 245

Daikin FTXS-L Series
414 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Indoor Unit: FTXS30/36LVJU SiUS091133
235 Removal Procedure
10
Unfasten the hook on
the right of the signal
receiver PCB.
(Then the signal
receiver PCB is lifted
up.)
11
Remove the signal
receiver PCB.
12
Disconnect the
connector.
[S48]: control PCB
Step
Procedure Points
(R13519)
Signal receiver PCB
Signal receiver unit
(R9521)
(R9522)
[S48]

Table of Contents

Other manuals for Daikin FTXS-L Series

Related product manuals