Loading...
SiUS091133 Indoor Unit: FTXS30/36LVJU
Removal Procedure 252
5
Remove the motor
mounting plate.
When reassembling the fan
motor and the fan rotor, provide
as much as 5 mm (0.2 inch) of
play between the side face of
the rotor and the bottom frame.
(1) Insert the fan motor with approx.
5 mm (0.2 inch) left.
(2) Tighten the screw until it stops.
Then give the screw one more
turn.
(3) Rotate the fan rotor and confirm
the fan motor and the fan rotor
are installed appropriately.
(4) Tighten the screw completely if
appropriate.
(5) If not appropriate, go back to
(1).
6
Remove the fan motor.
Step
Procedure Points
(R9564)
Motor mounting plate
5 mm (0.2 inch)
Side face of rotor
(R2808)
Side face of
bottom frame
(R9582)
(R9565)
Fan motor

Table of Contents