SiUS091133 Outdoor Unit: RXS15/18LVJU
Removal Procedure 324
3
Remove the putty.
Warning
Use caution to avoid burning
yourself with pipes and other
parts that are heated by the gas
brazing
Warning
If the refrigerant gas leaks during
work, immediately ventilate the
room. If refrigerant gas is
exposed to flames, toxic gas may
be generated.
Warning
If the refrigerant oil in the
compressor catches fire, have a
wet cloth prepared to extinguish
the fire immediately.
Caution
For global environmental
protection, do not discharge the
refrigerant gas in the
atmosphere. Make sure to collect
all the refrigerant gas.
4
Remove the 2 nuts of
the compressor.
Before working, make
sure that the refrigerant
gas is empty in the circuit.
Be sure to apply nitrogen
replacement when
heating up the brazed
part.
Step
Procedure Points
(R16963)
(R10257)